1. Start compressor; look for excessive vibration, lubricant leaks, proper operating temperatures
and pressures.
2. Observe operating temperature until stabilized. If the air temperature continues to rise above
180 °F (*82 °C), shut down the compressor and investigate the cause.
3. Maximum pressure is limited by available power. Do not exceed motor name plate rating for
service factor amps or safety valve setting.
4. Completely fill out the daily record card (example shown in Addendum 1). Be sure to take
voltage and amperage readings at constant pressure and with the compressor loaded. A
separate start-up form is provided with each new air compressor. The form needs to be
completely filled out and sent back to the factory for warranty purposes.
5. Test high temperature safety shutdown for proper operation by lowering the trip setting in the
CDP controller until the compressor shuts down. Compare the CDP setting with the oil
temperature. They should be similar values.
6. Another method for testing the high temperature shut down would be to raise the fan
temperature turn on set point to 237 °F (114 °C). The fan will not start until this temperature is
reached. If the high temperature shut down is working properly the compressor will shut down at
235 °F (113 °C). RESET THE FAN TEMPERATURE TURN ON SET POINT BACK TO
FACTORY SETTINGS (60 °F (16 °C)).
6.2
Starting Unit (After Initial Start Up)
1. Ensure lubricant is present in lubricant sight tube.
2. Press start button.
3. Watch operating temperature while unit pressure rises.
4. Observe operating parameters, check readings against normal operating ranges.
5. Check for lubricant leaks.
6. Make notations on Daily Record Card as indicated.
7. KI and KIV units are equipped with a restart delay initially set at 30 seconds. The unit will
not restart until this timer has counted down to zero after the previous stop.
6.3
Stopping Unit (Normal Shut Down)
1. Press stop button on the controller. The blow-down valve will automatically depressurize the
reservoir. The machine will continue to run for a pre-determined time (stop delay – initially set at
45 seconds) to stabilize unloaded operation before it shuts down the main motor. Once stopped
the restart delay counter will begin its countdown. The unit cannot start until this counter has
reached zero.
2. Do not use the Emergency Stop Button to shut the unit down under normal conditions. The
Emergency Stop Button is intended for use during emergency only. Emergency Stop is a harsh
and abrupt stop. While intermittent use of this feature should not significantly damage the
compressor, repeated use increases the risk of damage to the compressor.
Summary of Contents for KI Series
Page 1: ...1 Model __________________ Serial __________________ Rotary Screw Air Compressors...
Page 8: ...7 INTENTIONALLY BLANK...
Page 9: ...8 CHAPTER 1 GENERAL INFORMATION...
Page 19: ...10 CHAPTER 2 INSTALLATION INSTRUCTIONS...
Page 26: ...17 CHAPTER 3 ELECTRICAL INFORMATION...
Page 30: ...21 CHAPTER 4 COMPRESSOR LUBRICANT...
Page 39: ...30 INTENTIONALLY BLANK...
Page 40: ...31 CHAPTER 5 AIR INLET FILTER INFORMATION...
Page 43: ...34 INTENTIONALLY BLANK...
Page 44: ...35 CHAPTER 6 COMPRESSOR OPERATIONS...
Page 49: ...40 INTENTIONALLY BLANK...
Page 50: ...41 CHAPTER 7 TROUBLESHOOTING...
Page 57: ...48 CHAPTER 8 FORMS RECORDS AND ELECTRICAL SCHEMATICS...
Page 58: ...49...
Page 59: ...50...
Page 60: ...51...
Page 61: ...52...
Page 62: ...53...
Page 63: ...54...
Page 64: ...55...
Page 65: ...56 INTENTIONALLY BLANK...
Page 66: ...57...