29.
Lubricant from inside the lubricant separator elements is returned to the inlet valve or air end by way of a
scavenger tube positioned inside the lubricant separator element and via a tube to the compressor or inlet
valve.
Cleaning of the scavenging system should be performed.
1. When no lubricant is seen moving through the sight glass(es). (See Figure 4)
2. When excessive lubricant carry-over is detected.
3. When separator elements are changed.