English
45
Z21
®_
Booster
CV-Nr.
Meaning
r / w (CAN)
Value
Settings for Track Output 1
100
Track voltage & RailCom
®
: automatically accept default val-
ues from the control centre via CAN:
0=OFF, 1=ON
read / write
1
101
Track voltage default values in 100 mV increments:
values range: 120-240 (i.e. 12-24 V)
read / write
180
102
Activate RailCom
®
, i.e. generate RailCom
®
cutout:
0=OFF, 1=ON
read / write
1
110
Forward RailCom
®
Channel 2 data to the control centre via
CAN: 0=OFF, 1=ON
read / write
1
111
Activate DCC brake generator mode:
0=OFF, 1=ON
read / write
0
112
Report short circuit to control centre:
0=OFF, 1=ON
read / write
1
113
Activation auto-inversion:
0=OFF, 1=ON
read / write
0
120
Short circuit detection:
Values range: 20 (normal) ... 255 (fast)
read / write
20
121
Auto-inversion:
Values range: 5 (fast) ... 255 (slow)
read / write
20
Settings for Track Output 2 (only 10807 Dual Booster)
200
Track voltage & RailCom
®
: automatically accept default val-
ues from the control centre via CAN:
0=OFF, 1=ON
read / write
1
201
Track voltage default values in 100 mV increments:
values range: 120-240 (i.e. 12-24 V)
read / write
180
202
Activate RailCom
®
, i.e. generate RailCom
®
cutout:
0=OFF, 1=ON
read / write
1
210
Forward RailCom
®
Channel 2 data to the control centre via
CAN: 0=OFF, 1=ON
read / write
1
211
Activate DCC brake generator mode:
0=OFF, 1=ON
read / write
0
212
Report short circuit to control centre:
0=OFF, 1=ON
read / write
1
213
Activation auto-inversion:
0=OFF, 1=ON
read / write
0
220
Short circuit detection:
Values range: 20 (normal) ... 255 (fast)
read / write
20
221
Auto-inversion:
Values range: 5 (fast) ... 255 (slow)
read / write
20