7-20
Options
Accu-Stop Option
Figure 7.16 Accu-Stop Option Sequence of Operation
①
When Accu-Stop push button is closed, start/stop function is disabled.
Motor
Speed
100%
Push Buttons
Start
Stop
Accu-Stop
Auxiliary
Contacts
Normal
Up-to-speed
Open
Open
Open
Closed
Closed
Closed
Start
Run
Slow
Speed
Accu-Stop
Braking
Slow Speed
Braking/Coast
➀
Time (seconds)
If Stopping Current is set to 0%.
Slow Speed
!
ATTENTION:
The user is responsible for
determining which stopping mode is best suited to the
application and will meet applicable standards for
operator safety on a particular machine.
Summary of Contents for SMC Dialog Plus
Page 46: ...2 20 Installation ...
Page 78: ...4 14 Programming ...
Page 149: ...9 6 Diagnostics ...
Page 157: ...10 8 Troubleshooting Figure 10 3 Removal of Control Module 180 360A 1 3 2 4 ...
Page 169: ...A 6 Specifications ...
Page 179: ...C 4 Renewal Parts ...