Parameter Descriptions
12-21
89
Logic Source Sel
Range:
0 = Terminal Blk
1 = Local OIM
2 = DPI Port 2
3 = DPI Port 3
4 = Reserved
5 = Network
6 = Reserved
7 = All Ports
Default:
1 = Local OIM
Access:
0
Path: Speed Command>Control Src Select
See also:
90
!
ATTENTION: Changing parameter 89 to Terminal
Blk or Network while LevelSense Start is enabled
may start the drive if a start command is on from the
newly selected logic source.
When LevelSense Start is enabled, the user must
ensure that automatic start up of the driven
equipment will not cause injury to operating personnel
or damage to the driven equipment. In addition, the
user is responsible for providing suitable audible or
visual alarms or other devices to indicate that this
function is enabled and the drive may start at any
moment. Failure to observe this precaution could
result in severe bodily injury or loss of life.
ATTENTION: Removing and replacing the LCD OIM
while the drive is running may cause an abrupt speed
change if the LCD OIM is the selected reference
source, but is not the selected control source. The
drive will ramp to the reference level provided by the
OIM at the rate specified in Accel Time 1 (140), Accel
Time 2 (141), Decel Time 1 (142) and Decel Time 2
(143). Be aware that an abrupt speed change may
occur depending upon the new reference level and
the rate specified in these parameters. Failure to
observe this precaution could result in bodily injury.
ATTENTION: Note the following about stop
commands:
• A stop command from any attached OIM will always
be enabled regardless of the value of Logic Source
Sel.
• Network stop commands are effective only when
Logic Source Sel is set to Network or All Ports.
• Terminal block stop commands are effective only
when Logic Source Sel is set to Terminal Blk or All
Ports.
Failure to observe these precautions could result in
severe bodily injury or loss of life.
Summary of Contents for Reliance electric 6SP201-015
Page 14: ...1 2 SP600 AC Drive User Manual ...
Page 54: ...Mounting the Drive 3 16 ...
Page 82: ...6 12 SP600 AC Drive User Manual ...
Page 96: ...7 14 SP600 AC Drive User Manual ...
Page 232: ...Parameter Descriptions 12 102 ...
Page 280: ...B 8 SP600 AC Drive User Manual ...
Page 282: ...C 2 SP600 AC Drive User Manual ...
Page 284: ...D 2 SP600 AC Drive User Manual ...
Page 298: ......
Page 299: ......