G-7
Drive Regulation Overview
Figure G.6 – Vector Speed PI and Iq Reference Limit Selection
f(P.005,
U.006)
Iq ref high limit
Iq ref low limit
hi
hi
hi
low
low
low
f(P.025)
None
RMI
Netw
P.000 = OP
Netw com active
Netw Speed PI low limit
(drop 1, reg 60)
Netw Speed PI high limit
(drop 1, reg 59)
Current Limit (P.005)
Magnetizing Current (U.006)
high
high
high
low
Option board
type
low
low
Iq ref limits
Speed PI high limit
Speed PI low limit
"Netw" can be AutoMax, ControlNet, or DeviceNet
Netw speed PI limit enable
(drop 1, reg 53, bit 2)