Parameter Descriptions
3-91
Assigns an input function to the drive’s digital inputs.
To access Preset Speed 1, set Speed Ref x Sel to Preset Speed 1.
48 =Set Home
49 = Find Home
50 = Home Limit
51 = Vel Override
52 = Pos Sel 1
53 = Pos Sel 2
54 = Pos Sel 3
55 = Pos Sel 4
56 = Pos Sel 5
57 = Prof Input
Default:
See table 11.6
Access:
361= 0
362-366 = 1
Path:
Inputs & Outputs>Digital Inputs
See also:
96, 100, 124, 140, 156, 162, 194, 380
1
When Digital lnx Sel is set to 2 = Clear Faults, the Stop button cannot be used to clear a fault condition.
2
Typical 3-wire Inputs: Only 3-wire functions are allowed. Including 2-wire selections will cause a type 2 alarm.
3
Typical 2-wire Inputs: Only 2-wire functions are allowed. Including 3-wire selections will cause a type 2 alarm.
361
362
363
364
365
366
Digital In1 Sel
Digital In2 Sel
Digital In3 Sel
Digital In4 Sel
Digital In5 Sel
Digital In6 Sel
Table 3.4 – Speed Select Inputs
Speed Select Inputs (17,16,15)
3
2
1
Reference Source
0
0
0
Reference A
0
0
1
Reference B
0
1
0
Preset Speed 2
0
1
1
Preset Speed 3
1
0
0
Preset Speed 4
1
0
1
Preset Speed 5
1
1
0
Preset Speed 6
1
1
1
Preset Speed 7