3-118
DBT Reach Drive User Manual
Sets the amount of time between commanding the brake to release and the start of
drive acceleration. In Encoderless mode, this parameter sets the time to release the
brake after the drive starts.
Sets the amount of time the drive is below Float Tolerance (606) before the brake is
set. Not used in Encoderless Torque Prove mode.
Sets the frequency level where the float timer starts. Also sets the frequency level
where the brake will be closed in Encoderless Torque Prove mode.
Defines the amount of delay time between commanding the brake to be set and the
start of brake proving.
604
Brk Release Time
Range:
0.00 to 10.00 sec [0.01 sec]
Default:
0.10 sec
Access:
2
Path:
Applications>Torque Proving
See also:
605
ZeroSpdFloatTime
Range:
0.1 to 500.0 sec [0.1 sec]
Default:
5.0 sec
Access:
2
Path:
Applications>Torque Proving
See also:
606
Float Tolerance
Range:
0.1 to 5.0 Hz or 3.0 to 150.0 RPM [0.1 Hz or 0.1RPM]
Default:
0.2 Hz or 6.0 RPM
Access:
2
Path:
Applications>Torque Proving
See also:
607
Brk Set Time
Range:
0.00 to 10.00 sec [0.01 sec]
Default:
0.10 sec
Access:
2
Path:
Applications>Torque Proving
See also: