3-144
DBT Reach Drive User Manual
This integral gain adjusts the output voltage in response to the q and d axis motor
currents. A larger value increases the output voltage change.
This proportional gain adjusts the output voltage in response to the q and d axis motor
currents. A larger value increases the output voltage change.
Reserved. Do not adjust.
Reserved. Do not adjust.
511
KI Cur Reg
Range:
0 to 32767 [1]
Default:
44
Access:
2
Path:
Utility>Diag-Motor Cntl
See also:
512
Kp Cur Reg
Range:
0 to 32767 [1]
Default:
1600
Access:
2
Path:
Utility>Diag-Motor Cntl
See also:
513
PWM DAC Enable
Range:
0 to 1 [1]
Default:
0
Access:
2
Path:
Utility>Diag-DACS
See also:
514
515
516
517
DAC47-A
DAC47-B
DAC47-C
DAC47-D
Range:
0 to 7432 [1]
Default:
0
Access:
2
Path:
Utility>Diag-DACS
See also: