3-36
DBT Reach Drive User Manual
Present value of the PI feedback signal.
Present value of the PI error signal.
Present value of the PI output signal.
Provides filter for Process PI error signal. The output of this filter is displayed in PI
Error Meter (137). Zero will disable the filter.
.
136
PI Fdback Meter
Range:
-/+100.0% [0.1%]
Default:
Read Only
Access:
2
Path:
Speed Command>Process PI
See also:
124-138
137
PI Error Meter
Range:
-/+200.0% [0.1%]
Default:
Read Only
Access:
2
Path:
Speed Command>Process PI
See also:
124-138
138
PI Output Meter
Range:
-/+ 100.0 Hz or -/+ 800.0% [0.1 Hz or 0.1%]
Default:
Read Only
Access:
2
Path:
Speed Command>Process PI
See also:
124-138
139
PI BW Filter
Range:
0.0 to 240.0 Radians [0.1 Radians]
Default:
0.0 Radians
Access:
2
Path:
Speed Command>Process PI
See also:
137