Parameter Descriptions
3-77
Modules that are presently issuing a valid stop command.
Adapters that are presently issuing a valid start command.
Adapters that are presently issuing a valid job command.
Adapter that currently has exclusive control of direction changes.
288
Stop Owner
Range:
See figure 3.30
Default:
Read Only
Access:
2
Path:
Communication>Masks & Owners
See also:
276 - 285
Figure 3.30 – Stop Owner
0
0
0
1
0
0
x
x
x
x
x
x
x
x
x
x
10
0
1
2
3
4
5
6
7
8
9
11
12
13
14
15
1
=Issuing Command
0
=No Command
x =Reserved
Bit #
Digital In
DPI P
or
t 1
DPI P
or
t 2
DPI P
or
t 3
DPI P
or
t 4
DPI P
or
t 5
Reser
ved
Nibble 1
Nibble 2
Nibble 3
Nibble 4
289
Start Owner
Range:
See figure 3.30
Default:
Read Only
Access:
2
Path:
Communication>Masks & Owners
See also:
276 - 285
290
Jog Owner
Range:
See figure 3.30
Default:
Read Only
Access:
2
Path:
Communication>Masks & Owners
See also:
276 - 285
291
Direction Owner
Range:
See figure 3.30
Default:
Read Only
Access:
2
Path:
Communication>Masks & Owners
See also:
276 - 285