160
Rockwell Automation Publication KNX-TD005A-EN-P - October 2021
Kinetix 2090 Interface Cables
Kinetix 6000M Network Cables
Kinetix 6000M network cables provide motion commands to the IDM units. Kinetix 6000M network cables are available in lengths up to 25 m (82 ft).
The maximum combined cable length for all axes daisy-chained from the same IPIM module is 100 m (328 ft).
Typical Kinetix 6000M Network Cable Application
For example, in this Kinetix 6000M system, if each cable length was the maximum 25 m (82 ft), the combined cable length would be 75 m
(246 ft). The last IDM unit requires a 2090-CTSRP network terminator.
Kinetix 6000M Network Cables
Cat. No.
Description
Cable Configuration
Pin
Socket
2090-CNSSPSS-AA
xx
(1)
(1) Cables are available in standard lengths of 0.5, 1, 2, 3, 4, 5, 7, 9, 12, 15, 20, and 25 m (1.6, 3.2, 6.6, 9.8, 13.1, 16.4, 22.9, 29.5, 39.3, 49.2, 65.5, and 82.0 ft).
• Straight connector, pin (SP)
• Straight connector, socket (SS)
2090-CNSRPRS-AA
• Right-angle connector, socket (RP)
• Right-angle connector, socket (RS)
• Not compatible for connection to the IPIM module
2090-CNSRPSS-AA
xx
• Right-angle connector, socket (RP)
• Straight connector, socket (SS)
• Not compatible for connection to the IPIM module
2090-CNSSPRS-AA
xx
• Straight connector, pin (SP)
• Right-angle connector, socket (RS)
2090-CBUSPSS
• The network cable bulkhead adapter feeds signals through the cabinet wall
• Network cables attach on either side
2090-CTSRP
Network terminator
• Required on last IDM unit, right-angle, socket (RP)
• Included with each IPIM module
IMPORTANT
Right-angle (pin) connectors are not compatible for connection to the IPIM module. Only straight (pin) connectors fit properly.
Kinetix MDF
IDM Unit 3
2090-CNSSP
x
S-AA
xx
Network Cable 1
2090-CTSRP
Network Terminator
2094-SEPM-B24-S
IPIM Module
Kinetix MDF
IDM Unit 2
Kinetix MDF
IDM Unit 1
2090-CNS
x
P
x
S-AA
xx
Network Cable 3
2090-CNS
x
P
x
S-AA
xx
Network Cable 2
This cable end
must be a straight
(pin) connector.
These cable ends can be
straight or right-angle
connectors