Rockwell Automation Publication KNX-TD005A-EN-P - October 2021
133
Common Accessories
Technical Specifications - Bulletin 1394 Passive Shunt Modules
Select one of these Bulletin 1394 passive shunt modules when your Kinetix 6000, Kinetix 6200 or Kinetix 6500 drive application exceeds the
capacity of the internal (IAM/AM module) shunt resistor. These external passive shunt modules wire to the Kinetix 6000 (catalog number 2094-BSP2)
shunt module.
Dimensions - Shunt Resistor Kits
Catalog Numbers 1394-SR9A and 1394-SR9AF
External Shunt
Cat. No.
Voltage Class
Resistance
Ω
Peak Power
kW
Peak Current
A
Cont. Power
W
Shipping Weight,
approx
kg (lb)
Bussmann
Replacement
Fuse
1394-SR9A
200V
4
41.0
101.25
300
3.63 (8)
FNQ-R-20-R1
(1)
(1) Requires the use of an FNQ fuse with an adapter to allow the smaller body fuse to fit the larger FWP fuse holder.
400V
160
200
FWP50A14F
1394-SR9AF
200V
4
41.0
101.25
900
3.63 (8)
FNQ-R-20-R1
400V
160
200
FWP50A14F
1394-SR36A
200V
4
41.0
101.25
1800
8.6 (19)
FNQ-R-20-R1
400V
160
200
FWP50A14F
1394-SR36AF
200V
4
41.0
101.25
3600
9.0 (20)
FNQ-R-25-R1
400V
160
200
FWP50A14F
280
(11.0)
125
(4.9)
8.0
(0.31)
10.1
(0.40)
15.9
(0.63)
12.0
(0.47)
8.0
(0.31)
BULLETIN 1394 300W SHUNT MODULE
ALLEN-BRADLEY
FOR USE WITH 1394-SJT22-X SYSTEM MODULE
CAT.
PART
SER.
INPUT DC
INPUT AC
FOR FUSE REPLACEMENT USE:
BUSSMAN CAT. NO.
R
Shunt Module
150
(5.9)
25.0
(0.98)
8.0
(0.32)
100
(3.9)
25
(0.97)
155
(6.1)
(1)
175
(6.9)
Front View
Dimensions are in mm (in.)
Side View
(1) Dimension shown is for mounting hardware
location and does not reflect the location of
the lower slot radius.
All slots accept M6 or
1/4-20 mounting screws.