Rockwell Automation Publication 2198-UM001D-EN-P - May 2014
83
Connecting the Kinetix 5500 Drive System
Chapter 5
Motor Feedback Connections
Single motor cable feedback connections are made by using the
2198-KITCON-DSL feedback connector kit.
Figure 48 - MF Connector Wiring
Table 40 - Motor Feedback (MF) Connector Specifications
IMPORTANT
When using the 2198-KITCON-DSL feedback connector kit, the ambient
temperature for the Kinetix 5500 drive enclosure is 0…50 °C (32…122 °F).
Motor Cable
Shield Clamp
Motor Feedback
Connector Kit
2198-KITCON-DSL
Feedback Connector Kit
Connector
Housing
Refer to Kinetix 5500 Feedback Connector
Kit Installation Instructions, publication
, for connector kit specifications.
Internal
Grounding Plate
Clamp Screws (2)
Mounting Screws (2)
Exposed Shield
Feedback Cable
(EPWR+, EPWR-)
Cover
Kinetix 5500 Servo Drive
(front view)
2090-CS
x
M1DF-18AA
xx
Motor Cable
IMPORTANT
Cable preparation and positioning that provides a high-frequency bond
between the shield braid and grounding plate is required to optimize
system performance.
Drive Cat. No.
Pin
Signal/
Wire Color
Wire Size
AWG
Strip Length
mm (in.)
Torque Value
N•m (lb•in)
2198-H
xxx
-ERS
x
MF-1
D+/Blue
22
10.0 (0.39)
0.4 (3.5)
MF-2
D-/White/Blue
IMPORTANT
The feedback bundle in 2090-CS
x
M1DF-18AA
xx
motor cables (typically used
with frame 1 drives) route around the shield clamp (as shown in
The feedback bundle in 14 and 10 AWG cables (typically used with frame 2
and 3 drives) route with the power and brake wires inside the cable shield.