![Rockwell Automation 700-1308-00 Service Manual Download Page 95](http://html1.mh-extra.com/html/rockwell-automation/700-1308-00/700-1308-00_service-manual_1475097095.webp)
Maintenance
Repair
MagneMover LITE Service Manual
95
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
Disassemble Tandem Puck Assembly
1.
Remove the tandem puck from the MagneMover LITE transport system (see
2.
Place the tandem puck linkage plate installation fixture (shown in
surface.
3.
Place the tandem puck in the fixture as shown in
Figure 29: Place Tandem Wheeled Puck in Fixture
4.
Remove the two screws and washers that secure the linkage plate to the two pucks as
shown in
5.
Lift the linkage plate off of the pucks.
6.
With both pucks in the fixture, hold the left puck in place and lift the right puck out of
the fixture and away from the left puck.
CAUTION
Strong Magnets
To avoid injury from strong magnetic attractive
forces:
•
Handle only one puck at a time.
•
Do not place any body parts, such as fingers,
between the puck and any ferrous material or
another magnet array.
•
Pucks not being used must be secured individu-
ally in isolated packaging.
Tandem Puck
Installation
Fixture