![Rockwell Automation 700-1308-00 Service Manual Download Page 44](http://html1.mh-extra.com/html/rockwell-automation/700-1308-00/700-1308-00_service-manual_1475097044.webp)
Maintenance
Preventive Maintenance
44
MagneMotion
Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
Clean or Replace the Power Supply Air Filter
The filter in the MM LITE power supply must be removed and cleaned if it is dirty or replaced
if it is damaged.
Required Tools and Equipment
•
Small screwdriver, flat blade.
•
Filter replacement (if needed).
Procedure
Figure 10: Replacing Power Supply Fan Filter
1.
Turn off power to the MM LITE Power Supply.
NOTE:
Do not use the power supply when the filter is not installed.
2.
Visually inspect the air filter. If the filter is damaged or requires cleaning, remove the
filter from the power supply. Use a small screwdriver with a flat blade and gently
insert it between the front plate and the bezel of the filter housing near one of the
retaining clips and twist it slightly to release the front plate.
3.
Remove the front plate and the filter.
4.
To clean, wash both the front plate and the filter in warm soapy water, rinse using
clean water, and pat dry using paper towels.
5.
To replace, discard the old filter and unpack the new filter.
A replacement 60 mm x 60 mm filter can be ordered from a hardware supplier, such as
McMaster-Carr (#19155K7).
6.
Replace the air filter in the power supply by positioning it and snapping the cover into
place over it
7.
Return the power supply to normal operation.
Filter
Front Plate