Adjusting Vehicle Bearings
Properly adjusted bearings enable the vehicle to move easily along both straight and curve
rails with little movement between the bearings and the rail. Improperly adjusted bearings can
cause the motors to overheat if they are too tight on the rail or loss of precision if they are too
loose.
Figure 14: Precision Rail Vehicle Bearing Adjustment
CAUTION
Strong Magnets
To avoid severe injury, people with pacemakers and other
medical electronic implants must stay away from the magnet
array on the vehicle.
To avoid injury from strong magnetic attractive forces:
•
Handle only one vehicle at a time.
•
Do not place any body parts, such as fingers, between a
vehicle or magnet array and any ferrous material or
another magnet array.
•
Vehicles or magnet arrays not being used must be secured
individually in isolated packaging.
To avoid damage to watches, instruments, electronics, and
magnetic media, keep metal tools, metal objects, magnetic
media (memory disks/chips, credit cards, and tapes) and elec-
tronics away from the magnet arrays.
Eccentric
Bearing
Bearing Nut
Motor Side of Vehicle
Concentric
Bearing