Rockwell Automation Publication MMI-UM037A-EN-P - April 2020
6.
Remove the shims from the top of the magnet array and store them for reuse.
7.
Locate the replacement magnet array and place flat on the work surface away from the
vehicle.
8.
Place the previously removed shims on the top surface of the replacement magnet
array. Slide the shims around the array posts but do not allow the ends to extend
beyond the outer edges of the array.
NOTE:
If the shims are removed, or additional shims added, the length of the screws
must be adjusted appropriately.
9.
Place the mounting holes on the vehicle over the array posts. Realign the shims if nec-
essary to make sure that they align with the vehicle.
10.
Secure the array to the vehicle with the two M4 x 12 mm screws that were removed in
and Loctite 243. Tighten each screw to 1.5 N•m [13 in•lb].
NOTE:
The Loctite must cure for 2 hours at 22° C [72° F] before using the vehicle.
11.
Replace the vehicle, see
Replace Precision Rail Vehicles
12.
Restart the path.
13.
Dispose of the removed magnet array appropriately.