Palletizing Solution - Instruction Manual
l
Red flashes at slow rate.
i. Check the DB-9 connector.
ii. Check the cable.
iii. Check the communication parameters from the Robotiq User Interface, see recovery procedure.
iv. Contact support.
l
Red and green flashing at high speed.
i. Check fault status, maximum operating temperature could be exceeded.
ii. Contact support.
When using AirPick vacuum gripper with Universal Robots package:
Troubleshooting from the previous section (LED references) still applies.
From the UR teach pendant:
URCap install:
1. Verify that the latest URCap is installed from the Robot Setup menu, inside the URCaps tab
a. URCaps installation instructions are in the Installation section
b. Inside the URCaps tab, if you select the appropriate URCap file, you can see the current software version
c. Gripper toolbar should appear if installed properly
2. URCap is installed but Gripper cannot be controlled :
1. If Gripper LED is not blue, follow the steps in the first section above
2. If Gripper LED is blue, URCap is installed with the latest available version, contact
1. Verify that the latest URCap is installed by tapping the triple bar icon in the upper right corner, selecting Settings, then tapping
the System menu and the URCaps button in the navigation pane on the left
a. URCaps installation instructions are in the Installation section
b. Inside the URCaps menu, if you select the appropriate URCap file, you can see the current software version
c. The Gripper toolbar should appear if installed properly
2. URCap is installed but Gripper cannot be controlled :
1. If Gripper LED is not blue, follow the steps in the first section above
2. If Gripper LED is blue, URCap is installed with the latest available version, contact
Driver package install:
1. Driver checkup :
a. Use the latest driver version available at support.robotiq.com
l
Use the installation instruction from the Installation section
89
Summary of Contents for PALLETIZING SOLUTION
Page 12: ...Palletizing Solution Instruction Manual 12...
Page 72: ...6 1 2 AirPick Vacuum Gripper Fig 6 1 AirPick general dimensions 72...
Page 73: ...Palletizing Solution Instruction Manual 6 1 3 Extra Reach Bracket 73...
Page 74: ...6 1 4 Bracket for two 2 Suction Cups Fig 6 2 Two air nodes bracket s dimensions 74...
Page 80: ...80...
Page 95: ...1 2 2 Safety Connections Fig 12 2 Universal Robots Controller Safety Connections Schema 95...