Palletizing Solution - Instruction Manual
Wire #
Color
Function
Description
1
White
Safety-Reset
l
When using area scanner: Connect wire #1 to available 24V in UR controller. The system will auto-
start when you step out of the protected area.
l
When using light curtain: Connect wire #1 to normally-open (NO) reset switch. Connect switch's
second pole to available 24V in UR controller. Place reset switch outside of the protected area.
2
Brown
0V
0V link between both electrical enclosures.
3
Green
UR E-Stop Status 1
E-Stop status signal when a emergency signal is applied to EI0.
4
Yellow
UR E-Stop Status 2
E-Stop status signal when a emergency signal is applied to EI1.
5
Grey
UR Safeguard input 1
UR does not support a safeguard status in configurable outputs. Connect this pin to the regular
safeguard input SI0 for status.
6
Pink
UR Safeguard input 2
UR does not support a safeguard status in configurable outputs. Connect this pin to the regular
safeguard input SI1 for status.
Table 12-1: Safety Wires Description