8. Connect the 8 mm air tube to the vacuum generator. Follow the steps bellow:
Step #1
Step #2
Step #3
Insert the air tube in the AirPick port
Insert the safety clip
Ensure the safety clip is properly
installed
Info
Use dry and filtered air only. Follow standard ISO 8573-1, class 3.4.3. We recommend using a local pressure regulator with a
filter and air dryer.
9. Use the spiral cable sleeve to keep the air tube and the coupling cable together.
10. Plug the other extremity of the air tube to your local air supply devices.
Caution
l
Maximum pressure allowed is 7 bar (recommended pressure is 6.5 bar).
l
We recommend using a local pressure regulator with a filter and an air dryer.
11. Install the small cover on the side of the column with the provided screws.