Profile
Nominal Capacity
- is adjustable between 100mAh and 9900mAh with a stepwidth of 100mAh and
between 10000mAh and 25000mAh with a stepwidth of 1000mAh.
Nominal capacity means the nominal capacity of the battery which is in use.
- The value is used to calculate the estimated charge/discharge time.
In combination with the maximum capacity it is a charge end mechanism.
13
Charge current
- depending on the selected charge mode the value is adustable between 0.1A and 10A
or 8A with a stepwidth of 0.1A.
- Note, there is no capacity-controlled limit of the charge current for LiPO batteries.
General LiPO batteries should be charged with a maximum charge current of 1C, which
means a battery with a nominal capacity of 5000mAh should be charged with a maximum
charge current of 5A.
- Note, that this setting depends on previous settings and is maybe not shown.
Cells
- depending on the selected battery type values between 1-12, 1-4 or 1-6 are available.
Set the number of cells in series your battery consists of.
- Note, that this setting depends on previous settings and is maybe not shown.
deltaPeak / cell
- is adjustable between 1mV and 30mV with a stepwidth of 1mV.
- DeltaPeak is the main charge end mechanism with NiMH/Cd batteries.
- Note, that this setting depends on previous settings and is maybe not shown.
Peak-locktime
- is adjustable from 1min to 50min with a stepwidth of 1min.
- Peak-locktime is a countdown started with the charge.
During the countdown there is no check on deltaPeak and the peaklock symbol is shown.
This is very useful with old batteries which often generates a first peak at the beginning
of the charge.
- Note, that this setting depends on previous settings and is maybe not shown.