Cycle charge & discharge
How to start a cycle process
To start a cycle process you have to choose a profile
with an activated cycle function. This selection can
be done in the charge or discharge mode.
- The button within the charge or discharge
mode will start the cycle charge & discharge dialog..
- Confirms and starts the cycle according to
the adjustment with charging resp. discharging
the battery.
- exits the cycle start.
Current
cycle
During a cycle
You can see the number of the currently running cycle in
the right hand upper corner of the screen.
- Every button with the exception of can be
used as usual, just like known from the regular
charge or discharge mode.
How to stop a running cycle
- The button has to be pressed to stop a running
cycle. To avoid an accidental stop of a running cycle,
an additional dialog follows.
- Pressing is a confirmation and stops the running
cycle process.
- Pressing ends the dialog and keeps the cycle
process running.
24
ENTER /
START
MODE /
CANCEL
ENTER /
START
MODE /
CANCEL
MODE /
CANCEL
ENTER /
START
MODE /
CANCEL
ENTER /
START
MODE /
CANCEL
Between active cycle steps
the system is waiting according to the adjustments until the
battery has reached the adjusted cooling-off temperature or
until the adjusted time delay has run out. Status information
about the delay period is provided via popups.
- The button overrules the adjusted cooling-off time
or temperature and starts immediately the next cycle step.
- PLEASE NOTE: that it might be possible, that after too
short of an cooling-off time the following charging could
be stopped way too early due to the high temperature of
the battery.
ENTER /