SECTION 11: O
PERATION
AND
M
AINTENANCE
59 of 71
Burner Observation
Window
Make s
u
re it is clean and free of cracks or holes.
Clean and replace as req
u
ired.
Blower Scroll, Wheel and
Motor
Compressed air or a
v
ac
uu
m cleaner may be
u
sed to clean d
u
st and dirt.
Burner Cup and Orifice
Clear of obstr
u
ctions (e
v
en spider
w
ebs
w
ill ca
u
se problems).
Caref
u
lly remo
v
e any d
u
st and debris from the b
u
rner.
Hot-Surface I
g
niter
Replace if cracked or broken.
Heat Demand Device:
Thermostat, Zone Sensor,
External Pot or 0-10 Vdc or
4 - 20 mA wirin
g
There sho
u
ld be no exposed
w
ire or damage to the de
v
ice or
w
iring.
See Page 39, Section 10
.
Suspension Points
Make s
u
re the heater is hanging sec
u
rely.
Look for signs of
w
ear on the chain or ceiling.
See Page 13, Figure 11
.
Decorative and Protective
Grille (optional)
The grille m
u
st be sec
u
rely attached.
Check that the side reflector extensions are installed correctly and sec
u
red in
place if necessary. (Decorati
v
e grille only.)
See Page 28, Section 7.5
and Page 30, Section 7.6
Make s
u
re shield is installed correctly and sec
u
red in place if necessary.
(Decorati
v
e grille only.)
See Page 29, Section 7.5.2
.
Lower Clearance Shield
(optional)
The lo
w
er shield m
u
st be sec
u
rely attached.
Inspect shield s
u
pport straps and lo
w
er clearance shield anchor points.
See Page 28, Section 7.4
.
Make s
u
re shield is installed correctly and sec
u
red in place if necessary.
See Page 28, Section 7.4
.
Silicone Tubin
g
Ens
u
re tight, sec
u
re fit on all press
u
re fittings at gas
v
al
v
e, press
u
re s
w
itch,
press
u
re sensor, b
u
rner partition, and blo
w
er o
u
tlet.
Gas Valve
Verify silicone t
u
bing has a tight sec
u
re fit on "
v
ent" fitting.
Verify that plastic cap on co
v
ering press
u
re reg
u
lator adj
u
stment scre
w
is
sec
u
re and has not been tampered
w
ith.
Do not remo
v
e plastic reg
u
lator cap or attempt to adj
u
st
v
al
v
e press
u
re
reg
u
lator.
Verify all
w
iring connections.
Wall Ta
g
If
w
all tag is present, make s
u
re it is legible and acc
u
rate. Please contact
Roberts-Gordon LLC or yo
u
r ROBERTS GORDON
®
independent distrib
u
tor, if
yo
u
need a
w
all tag.
See Page 4, Section 2.1
.
Summary of Contents for Energytube EM-115
Page 2: ......
Page 4: ......
Page 6: ......
Page 69: ...SECTION12 TROUBLESHOOTING 63 of 71 12 3 Troubleshooting Flow Chart ...
Page 70: ...EM SERIES INSTALLATION OPERATION AND SERVICE MANUAL 64 of 71 ...
Page 72: ...EM SERIES INSTALLATION OPERATION AND SERVICE MANUAL 66 of 71 12 5 Pneumatic Connections ...
Page 74: ...EM SERIES INSTALLATION OPERATION AND SERVICE MANUAL 68 of 71 ...
Page 78: ......
Page 80: ......
Page 81: ......