7. Life phases
42
7.4.2
RK
Slim
lift EM
To install the
RK
Slim
lift EM
, there are 9x M6 tapped holes
in the top plate
2
, (view X) 7 x Ø5.4
mm holes on the bottom
side, and 4 x M8 threaded holes in the base plate
3
. The
max. screw depth for M6 in the top plate is 8 mm, and 10
mm in the base plate for M8.
The recommended tightening torque for M6 is max. 10 Nm
and for M8 max. 15 Nm.
Motorised configuration
When connecting the optional controllers, please observe
the designation on the type plate of this
RK
Slim
lift
.
Limit switch
The
RK
Slim
lift
/
RK
Slim
lift EM
is equipped with two limit
switches. These prevent an overrunning of the maximum
lifting height as well as overrunning of the lower stop
position when using controllers intended for the
RK
Slim
lift
/
RK
Slim
lift EM
. When using another controller or direct
supply of current, the lifting columns can extend beyond the
limit switches and lead to their destruction.
Manual configuration (only
RK
Slim
lift
)
Adjustments are performed manually using a crank handle.
Operation
•
Insert the crank handle in the receptacle.
•
Turn to the right to raise the lifting column.
•
Turn to the left to lower the lifting column.