The flue must be well isolated and circular if possi-
ble. The flue must not have defects, narrowings or
losses. All the inspection doors must be closed and
well sealed. The connection of other devices to the
same chimney is not allowed.
The chimney pot must have an exit section dou-
bled than the one of the chimney, in order to make
easier the exit of the smoke. The chimney pot must
be enough tall to lean out over the reflow zone
generated by the roof: if you are not sure about
this contact experienced technicians. If you are
in a windy place, it might be necessary to install
windproof devices.
2.5 FLUE
2.6
CHIMNEY POT
The conjunction of the thermostove to the flue
must be as short as possible and must not have
horizontal or not much inclined parts. The counter-
slope parts are forbidden and must be absolutely
avoided.
Near the conjunction, inflammable materials must
not be present. The conjunction must not go inside
the flue. To increase the safety of the conjunction,
we suggest to install a washer on the wall being
sure that the connection between the washer and
the chimney is walled and well sealed. Also the
connection between the thermostove and the
conjunction must be fixed and sealed.
The device with T Art and T Rock finishes are deliv-
ered with the sides unfixed, inserted in a separated
package. Before the final placement of the device,
it is necessary to fix the covering of the sides. First
2.7 CONJUNCTION
2.8
SIDES FIXING (X ART AND X ROCK SERIES)
Picture 8 – Fixing of the covering elements of the sides and the cap of the stove (X Art and X Rock Series).
x24
x4
x4
A
C
B
D
Summary of Contents for T Art Basic
Page 1: ...Istruzioni d uso Gebrauchsanweisung Instructions Manuel d utilisation ...
Page 2: ......
Page 37: ...ITALIANO 35 ...
Page 71: ...DEUTSCH 69 ...
Page 105: ...ENGLISH 103 ...
Page 139: ...FRANÇAIS 137 ...
Page 140: ...138 ...
Page 141: ...139 ...
Page 142: ...140 ...
Page 143: ...FRANÇAIS 141 ...