Service
Service speech
184
4.2
Service indicators
TwinBus power supply unit 1 7573
Verrano glass door station
Indicator
Meaning
LED 1 (yellow) flashes
The door opener operating time is set (LED flashes every second when door
opening time is being set).
LED 2 (red) is lit
Indicates transmission of bus commands, e.g.:
handset has been picked up or replaced.
Doorbell is pressed.
Door opener or button
in operation.
Internal call or switching command initiated.
LED 2 (red) flashes
Start-up has been activated via the apartment button.
LED 3 (green) illuminates
Adjustment protection is activated.
LED 4 (red) illuminates
Overload or short circuit on the system bus.
LED 5 (green) illuminates
Door communication is enabled.
LED 6 (yellow) illuminates
Direct current indicator (bus voltage)
LED 7 (yellow) illuminates
Alternating current indicator (door opener)
LED 8 (red) illuminates
Door opener relay has switched.
Indicator
Meaning
LED 1 illuminates
in speech operation
Indicates an active speech connection.
LED 1 illuminates
for inactive speech operation
The LED indicates that the connections at terminal 1 and terminal 2 are
swapped.
"
&
%
#
$
!