143
Serial Interface
Command example
The example of a setting by a command is shown.
Using a request command after a setting is recommended.
Basic setting
Setting the time scale of time-level display to “20s”
Time
Level
Time
Scale, 20s
Setting the level range upper limit of X channel, Y channel and Z channel to
“10 m/s
2
”
Range
X, 1
Range
Y, 1
Range
Z, 1
When operating auto store
Setting the Store Mode to “Auto”
Store
Mode, Auto
Setting the Store Name to “0100”
Store
Name, 100
Setting the Total Measurement Time to “10min”
Measurement
Time
Preset
Auto, 10m
Setting the Inst Store Interval to “100ms”
Inst
Store
Interval, 100ms
Setting the Calculation Interval to “1min”
Calculation
Interval
Preset, 1m
Measurement start / stop (store)
Measure, Start
* No confi rmation about overwriting.
Measure, Stop
Measurement data acquisition
DOD?