129
Serial Interface
Acc Lower
Frequency weighting of Acc lower
Setting lower limit of frequency range for Acc.
Setting command
Acc
Lower, p1
Parameter p1=
“0.5Hz”
p1= “1Hz”
p1= “4Hz”
Request command Acc
Lower?
Response data
d1
Returned value
Same as for setting command
Acc Upper
Frequency weighting of Acc upper
Setting upper limit of frequency range for Acc.
Setting command
Acc
Upper, p1
Parameter p1=
“80Hz”
p1= “100Hz”
p1= “250Hz”
p1= “Sensor Dependent”
Request command Acc
Upper?
Response data
d1
Returned value
Same as for setting command
Vel Disp Build Lower
Frequency weighting of building Vel and Disp lower
Setting lower limit of frequency range for Building damage Vel. and Disp.
Setting command
Vel
Disp
Build
Lower, p1
Parameter p1=
“0.5Hz”
p1= “1Hz”
p1= “4Hz”
Request command Vel
Disp
Build
Lower?
Response data
d1
Returned value
Same as for setting command