46
Display
For displays marked by *, the buzzer does
not sound.
Safety Interlock
Function
Cause
Remedy
Reference
Page
<out>
*
Safety interlock at power outage
Gas supply and operation is stopped when a power
outage occurs. Also, the equipment cannot be used
during a power outage.
This is not an equipment malfunction.
This occurs because of a power outage or the power plug
was removed during operation.
When power is turned ON again, press
, then display is
. And cool
operation operates for approximately 80 minutes. In this case, wait for cool
operation to end before performing operation again.
-
<blinks>
<blinks>
Temperature detection thermistor
(blocked filter error)
Gas supply is stopped and cool operation is automatically
started when lint blocks the lint filter or when the inside of
the equipment overheats abnormally.
This occurs when there is insufficient air for combustion.
Wait approximately 80 minutes for cool operation to end before inspecting
and performing operation again. (When there is too much washing loaded
in the equipment, remove the clothing or remove clothing with poor
permeability, then perform operation again.)
24, 26,
40 to 42
Lint has accumulated on the lint filter or the lint filter is
blocked with lint.
Thin clothing with poor permeability is covering the lint
filter.
There is too much washing loaded in the equipment.
This occurs when dust has built up inside of the
equipment.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
The discharge tube is blocked.
<blinks>
Ignition/light out safety Interlock
Gas supply is stopped and cool operation is automatically
started when lighting of the pilot light fails during ignition.
This occurs, for example, when the gas cock is closed or
was not completely open.
Wait approximately 2 minutes for cool operation (replacement with fresh air)
to end before inspecting and performing operation again.
23
<blinks>
Gas supply is stopped and cool operation is automatically
started when flames go out during use.
This occurs, for example, when the gas cock is closed or
was not completely open.
Wait approximately 80 minutes for cool operation to end before inspecting
and performing operation again.
This occurs when oxygen in the room has dropped to a
very low level.
Perform operation again after sufficiently ventilating the room.
13
<blinks>
Temperature detection thermistor
(discharge temperature thermistor)
Gas supply is stopped and cool operation is automatically
started when the inside of the equipment overheats
abnormally.
The discharge tube is blocked.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
<blinks>
Temperature detection thermistor
(clothes temperature thermistor)
Gas supply is stopped and cool operation is automatically
started when the inside of the equipment overheats
abnormally.
Lint has accumulated on the lint filter or the lint filter is
blocked with lint.
Wait approximately 80 minutes for cool operation to end before cleaning the
lint filter for use. (When there is too much washing loaded in the equipment,
remove the clothing or remove clothing with poor permeability, then perform
operation again.)
26, 41, 42
There is too much washing loaded in the equipment.
<blinks>
Switch circuit safety interlock
Gas supply is stopped and cool operation is automatically
started when an abnormality occurs on the start/pause
switch circuit.
This occurs when the start/pause switch circuit short-
circuits or the switch is held down for 10 seconds or more.
Wait approximately 80 minutes for cool operation to end before inspecting
and performing operation again. Repair is necessary when operation
cannot be performed again. Contact the store of purchase or call Customer
Services Hotline.
-
<blinks>
Temperature detection thermistor
(blow temperature thermistor)
Gas supply is stopped and cool operation is automatically
started when the inside of the equipment overheats
abnormally.
Lint has accumulated on the lint filter or the lint filter is
blocked with lint.
Wait approximately 80 minutes for cool operation to end before cleaning the
lint filter for use. (When there is too much washing loaded in the equipment,
remove the clothing or remove clothing with poor permeability, then perform
operation again.)
24,26,
41,42
Thin clothing with poor permeability is covering the lint
filter.
There is too much washing loaded in the equipment.
The discharge tube is blocked.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
• Cooling operation stops temporarily when the front door is opened during cool
operation or when the “Start / Pause” switch is pressed. Cool operation is resumed
by closing the front door or by pressing the “Start / Pause” switch again. Wait for
cool operation to stop.
• For details on how to stop cool operation midway (turn the blinking display OFF),
see pages 29.
Information
• Even if inspection is performed according to the
descriptions in the table below, repair is necessary when
the safety interlocks frequently operate in the same way
or other messages are displayed. Contact the store of
purchase or call Customer Services Hotline.
Note