background image

 
E3830, E3860 & E3865 
DOMINATOR

PLUS 

Fryers

 

INSTALLATION and 
SERVICING INSTRUCTIONS

 

 

 
 
 
 
 

IMPORTANT

 

The installer must ensure that the installation of the appliance is in conformity with these instructions 
and National Regulations in force at the time of installation. Particular attention MUST be paid to:

 

 

BS7671 IEE Wiring Regulations 
Electricity at Work Regulations 
Health And Safety At Work Act 
Fire Precautions Act

 

 

This  appliance  has  been  CE-marked  on  the  basis  of  compliance  with  the  Low  Voltage  and  EMC 
Directives for the voltages stated on the data plate.

 

 

 

WARNING

THIS APPLIANCE MUST BE EARTHED.

 

 

On completion of  the installation,  these  instructions  should be  left  with the  Engineer-in-Charge for 
reference during servicing. Further to this, The Users Instructions should be handed over to the User, 
having had a demonstration of the operation and cleaning of the appliance.

 

 

IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING 
AND  COMMISSIONING  THIS  APPLIANCE.  FAILURE  TO  COMPLY  WITH  THE  SPECIFIED 
PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL.

 

 

PREVENTATIVE MAINTENANCE CONTRACT

 

In order  to obtain  maximum performance from this unit  we  would  recommend that a maintenance 
contract be arranged with 

SERVICELINE

. Visits may then be made at agreed intervals to carry out 

adjustments and repairs. A quotation will be given upon request to the contact numbers below.

 

 

WEEE Directive Registration No. WEE/DC0059TT/PRO  

At end of unit life, dispose of appliance and any replacement 
parts in a safe manner, via a licensed waste handler.

 

Units are designed to be dismantled easily and recycling of all 
material is encouraged whenever practicable.

 

 

 
 
 
 

Falcon Foodservice Equipment

 

HEAD OFFICE AND WORKS

 

Wallace View, Hillfoots Road, Stirling. FK9 5PY. Scotland.

 

SERVICELINE CONTACT

 

Phone: 01438 363 000 

Fax: 01438 369 900

 

T100774 Ref. 6

 

Summary of Contents for DOMINATORPLUS E3865

Page 1: ...n of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a maintenance contract be arra...

Page 2: ...ion systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems...

Page 3: ...ata plate SECTION 2 ASSEMBLY and COMMISSIONING 2 1 ASSEMBLY The appliance is supplied complete and ready to be connected to the mains supply Position unit in desired location and level it Turn lower section of each leg clockwise to raise corresponding corner height or anti clockwise to lower it Castors Undo grub screw and use a spanner to adjust the castor height Turn clockwise to raise level and ...

Page 4: ...d with small glands which must not be overtightened The phial must be fixed in position within pan before tightening gland The phial tip should protrude from protective tube by 33mm Thermostat capillary tube must be covered with sleeve insulation Safety stat phial should be located centrally within element clip 3 4 CONTACTOR This should require little or no maintenance under normal circumstances A...

Page 5: ...E3830 WIRING DIAGRAM ...

Page 6: ...E3830 CIRCUIT DIAGRAM ...

Page 7: ...E3860 WIRING DIAGRAM ...

Page 8: ...E3860 CIRCUIT DIAGRAM ...

Page 9: ...E3865 WIRING DIAGRAM ...

Page 10: ...E3865 CIRCUIT DIAGRAM ...

Reviews: