1.1 MODEL NUMBERS, NETT WEIGHTS 

and DIMENSIONS

 

 

Model

 

Width

 

(mm)

 

Depth

 

(mm)

 

Height

 

(mm)

 

Weight

 

(kg)

 

E3830 Fryer

 

300

 

770

 

890

 

45

 

E3860 Fryer

 

600

 

770

 

890

 

73

 

E3865 Fryer 

600 

770 

890 

85 

 

1.2 SITING

 

Before connecting appliance to electricity supply, it must 
be correctly positioned and levelled. Levelling is effected 
by  turning   the   lower   area   of   the   adjustable   legs. 
If desired, feet that allow floor-fixing may be specified at 
time of order.

 

 

1.3 ELECTRICAL CONNECTION

 

The  unit  is  designed  for  use  on  AC  supplies  only  and 
terminals  are  normally  arranged  for  either  2  phase 
operation 

(E3830  model) 

or  3  phase 

(E3860  &  E3865 

models)

.

 

If single phase supply has been specified, a bridging link 
is provided with the appliance and should be connected 
as detailed below.

 

 

Cable entry is located at appliance rear in the form of a 
cable gland.

 

A suitably rated isolating switch with contact separation of 
at least 3mm in all poles must be installed. All wiring must 
be executed in accordance with regulations listed on title 
page of this document.

 

Warning - This appliance must be earthed.

 

 

 

1.4 ELECTRICAL RATINGS

 

The electrical rating is stated on appliance data plate.

 

 
 

SECTION 2 -

 

ASSEMBLY and COMMISSIONING

 

2.1 ASSEMBLY

 

The  appliance  is  supplied  complete  and  ready  to  be 
connected to the mains supply.

 

Position unit in desired location and level it. Turn lower 
section  of  each  leg  clockwise  to  raise  corresponding 
corner height or anti-clockwise to lower it.

 

Castors

 

Undo grub screw and use a spanner to adjust the castor 
height. Turn clockwise to raise  level  and  anti-clockwise 
to lower.

 

Secure grub screw when task is completed.

 

 
 
 
 
 
 
 

 

Grub 
screw

 

 

 
 
 
 
 
 

2.2 CONNECTION TO THE ELECTRICAL SUPPLY

 

To gain access to terminals, proceed as follows:-

 

Remove fixings at unit rear to remove cover and access 
electrical connections.

 

Undo cable gland.

 

Feed cable through cable gland into electrical box. 

Connect leads to respective terminals.

 

Tighten cable gland. 

Replace cover.

 

If single phase connection is required, refer to Section 1.3 
for details.

 

 

2.3 COMMISSIONING

 

Fill   pan(s)   with   oil   to   mark    on    element    guard 

(i.e. approximately 20 litres for E3830 model and 40 litres 
for  E3860  &  E3865  models) 

and  switch  on  at    isolator  

switch.  Turn  thermostat  to  maximum  setting  and 
check  that  it  operates  at  the  correct  temperature  of 
190°C.

 

The  importance  of  never  switching  on  the  elements 
unless they are covered by oil or water must be stressed. 
DO NOT USE SOLID FAT.

 

 

2.4 INSTRUCTION TO USER

 

After installing and commissioning appliance, hand user 
instructions to user or purchaser.

 

Ensure that person

(s) 

responsible is 

(are) 

made familiar 

with use and maintenance of unit.

 

Summary of Contents for DOMINATORPLUS E3865

Page 1: ...n of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a maintenance contract be arra...

Page 2: ...ion systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems...

Page 3: ...ata plate SECTION 2 ASSEMBLY and COMMISSIONING 2 1 ASSEMBLY The appliance is supplied complete and ready to be connected to the mains supply Position unit in desired location and level it Turn lower section of each leg clockwise to raise corresponding corner height or anti clockwise to lower it Castors Undo grub screw and use a spanner to adjust the castor height Turn clockwise to raise level and ...

Page 4: ...d with small glands which must not be overtightened The phial must be fixed in position within pan before tightening gland The phial tip should protrude from protective tube by 33mm Thermostat capillary tube must be covered with sleeve insulation Safety stat phial should be located centrally within element clip 3 4 CONTACTOR This should require little or no maintenance under normal circumstances A...

Page 5: ...E3830 WIRING DIAGRAM ...

Page 6: ...E3830 CIRCUIT DIAGRAM ...

Page 7: ...E3860 WIRING DIAGRAM ...

Page 8: ...E3860 CIRCUIT DIAGRAM ...

Page 9: ...E3865 WIRING DIAGRAM ...

Page 10: ...E3865 CIRCUIT DIAGRAM ...

Reviews: