SECTION 3 - SERVICING and

 

MAINTENANCE

 

BEFORE  ATTEMPTING  ANY  MAINTENANCE  TASK, 
ISOLATE  THE  APPLIANCE  AT  THE  MAIN  SUPPLY. 
TAKE  STEPS  TO  ENSURE  THAT  IT  MAY  NOT  BE 
INADVERTENTLY SWITCHED ON.

 

 

3.1 ELECTRICAL CONTROL GEAR

 

The  mains  terminals  are  located  at  rear  of  unit.  The 
contactor(s) are  contained within box at front.

 

To  gain  access,  open  door  and  remove  cover  panel 
behind.

 

The control thermostat(s) and neon lamps are mounted 
on  the facia panel, which is secured by four fixings.

 

 

3.2 NEON INDICATOR LAMPS

 

These must be replaced by new lamps in event of failure.

 

To replace a faulty lamp, first remove facia panel and pull 
off push-on terminals. Remove lamp by undoing fixing nut 
at rear.

 

 

3.3 THERMOSTATS

 

The fryer has two thermostats.

 

The  adjustable  control  thermostat  is  mounted  upon 
control panel.

 

The safety thermostat is located within the element box. 
It has a fixed setting and manual re-set button at rear of 
element box. In the event of control thermostat failure and 
resultant  overheating  of  frying    medium,  safety 
thermostat  will  trip  supply  to  elements  before  oil 
temperature becomes dangerous.

 

To    restore     circuit     having     rectified     the     fault, 
it is necessary to press the re-set button. This is situated 
within the turret which projects through element box rear. 
The  oil  must  be  allowed  to  cool  to  enable  safety 
thermostat to be re-set.

 

A  defective  safety  or  control  thermostat  cannot  be 
repaired and must be replaced. The capillary tubes pass 
through pan wall and are sealed with small glands which 
must  not  be  overtightened.  The  phial  must  be  fixed  in 
position within pan before tightening gland. The phial tip 
should  protrude  from  protective  tube  by  33mm. 
Thermostat capillary  tube  must be  covered  with  sleeve 
insulation.  Safety  stat  phial  should  be  located  centrally 
within element clip.

 

 

3.4 CONTACTOR

 

This should require little or no maintenance under normal 
circumstances.  After  long  service,  the  contacts  may 
become pitted and at that point, new contacts should  be 
fitted.

 

3.5 ELEMENTS

 

These are individually replaceable. Access to terminals 
and  fixing  nuts  is  gained  upon  removing  element  box 
cover. When  fitting a  new  element,  ensure  that  sealing 
gasket is fitted and tighten fixing nut firmly, preferably with 
the aid of a tubular box spanner or socket.

 

When re-fitting element box cover, check condition of oil 
resistant  gasket.  Do  not  use  excessive  force  when 
securing cover as this may deform it and allow oil to enter 
box.

 

 

3.6 CLEANLINESS

 

To maintain maximum performance, the pan must be kept 
clean.  Periodically, oil must  be  drained off and  the  pan 
should be filled with water and detergent. Boil up contents 
and  drain  whilst  still  hot  before  flushing  out  with  clean 
water. Thoroughly dry pan and all fittings before re-filling 
with oil. The elements can be lifted and hinged backward 
to gain full access to all surfaces of pan and elements.

 

 

3.7 TILT SWITCH

 

Located in element terminal box, this component should 
require no maintenance.

 

 

 
 

SECTION 4 - SPARES

 

When  ordering  spares,  quote  the  unit  type  and  serial 
number.  This  information  will  be  found  on  data  plate 
located on cover panel behind door.

 

An identity label is also provided on front frame.

 

Summary of Contents for DOMINATORPLUS E3865

Page 1: ...n of the operation and cleaning of the appliance IT IS MOST IMPORTANT THAT THESE INSTRUCTIONS BE CONSULTED BEFORE INSTALLING AND COMMISSIONING THIS APPLIANCE FAILURE TO COMPLY WITH THE SPECIFIED PROCEDURES MAY RESULT IN DAMAGE OR THE NEED FOR A SERVICE CALL PREVENTATIVE MAINTENANCE CONTRACT In order to obtain maximum performance from this unit we would recommend that a maintenance contract be arra...

Page 2: ...ion systems Gas water and electrical supply external to unit Light bulbs Re installing vacuum in kettle jackets Replacement of grill burner ceramics when damage has been clearly caused by misuse Where an engineer finds no fault with a product that has been reported faulty Re setting or adjustment of thermostats when unit is operating to specification Cleaning and unblocking of fryer filter systems...

Page 3: ...ata plate SECTION 2 ASSEMBLY and COMMISSIONING 2 1 ASSEMBLY The appliance is supplied complete and ready to be connected to the mains supply Position unit in desired location and level it Turn lower section of each leg clockwise to raise corresponding corner height or anti clockwise to lower it Castors Undo grub screw and use a spanner to adjust the castor height Turn clockwise to raise level and ...

Page 4: ...d with small glands which must not be overtightened The phial must be fixed in position within pan before tightening gland The phial tip should protrude from protective tube by 33mm Thermostat capillary tube must be covered with sleeve insulation Safety stat phial should be located centrally within element clip 3 4 CONTACTOR This should require little or no maintenance under normal circumstances A...

Page 5: ...E3830 WIRING DIAGRAM ...

Page 6: ...E3830 CIRCUIT DIAGRAM ...

Page 7: ...E3860 WIRING DIAGRAM ...

Page 8: ...E3860 CIRCUIT DIAGRAM ...

Page 9: ...E3865 WIRING DIAGRAM ...

Page 10: ...E3865 CIRCUIT DIAGRAM ...

Reviews: