48
Display
For displays marked by *, the buzzer does
not sound.
Safety Interlock
Function
Cause
Remedy
Reference
Page
<blinks>
Drum rotation sensor
(drum rotation abnormality)
Gas supply is stopped and cool operation is automatically
started when the drum does not rotate or drum rotation is
insufficient.
There is too much washing loaded in the equipment.
Reduce the amount of washing, and perform operation again. (as a guideline
after spin drying, within 13 kg)
26, 37
The electrical circuit of a motor, etc. is malfunctioning.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
<blinks>
Fan rotation sensor
(discharge fan rotation abnormality)
Gas supply is stopped and cool operation is automatically
started when the discharge fan does not rotate, drum
rotation is insufficient or the drum rotates abnormally.
Thin clothes with poor permeability or a mat is covering
the lint filter.
Remove the clothes with poor permeability or the mat, then perform
operation again.
24
The discharge tube is blocked.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
The electrical circuit of a motor, etc. is malfunctioning.
<blinks>
Ignition/light out safety interlock
(ignition failure for 5 times
continuous)
Gas supply is stopped and cool operation is automatically
started when lighting of the pilot light fails (continuously
for 5 times) during ignition.
This occurs, for example, when the gas cock is closed or
was not completely open.
Wait approximately 2 minutes for cool operation (replacement with fresh air)
to end before inspecting and performing operation again.
23
<blinks>
Error can be
canceled
Drum rotation sensor
(drum rotation abnormality)
Gas supply and operation are stopped when the drum
does not rotate or drum rotation is insufficient.
There is too much washing loaded in the equipment.
Reduce the amount of washing, and perform operation again. (as a guideline
after spin drying, within 13 kg)
26, 37
Error cannot
be canceled
Fan rotation sensor
(discharge fan rotation abnormality)
The electrical circuit of a motor, etc. is malfunctioning.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
<blinks>
Overheat prevention device
(thermocouple)
Gas supply is stopped and cool operation is automatically
started when lint blocks the lint filter or when the inside of
the equipment overheats abnormally.
This occurs when there is insufficient air for combustion.
Wait approximately 80 minutes for cool operation to end before inspecting
and performing operation again. (When there is too much washing loaded
in the equipment, remove the clothing or remove clothing with poor
permeability, then perform operation again.)
24, 26,
40 to 42
Lint has accumulated on the lint filter or the lint filter is
blocked with lint.
Thin clothing with poor permeability is covering the lint
filter.
There is too much washing loaded in the equipment.
This occurs when dust has built up inside of the
equipment.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
The discharge tube is blocked.
<out>
*
Overheat prevention device
(temperature fuse)
Gas supply, operation are stopped when the inside of the
equipment overheats abnormally.
This occurs when there is insufficient air for combustion.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
24, 26,
40 to 42
Lint has accumulated on the lint filter or the lint filter is
blocked with lint.
Thin clothing with poor permeability is covering the lint
filter.
There is too much washing loaded in the equipment.
The discharge tube is blocked.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
Overcurrent prevention device
(current fuse)
The current fuse and gas supply and operation are
stopped when an overcurrent flows.
This occurs when an electrical circuit short-circuits.
Display other than the above
Safety interlocks other than the
above
A safe shutdown occurs when an abnormality other
than the above occurs.
Wait for the equipment to stop automatically before performing operation again. Repair is required when the safety interlock operates
again. Contact the store of purchase or call Customer Services Hotline.
-