Ventilation
• If no humidity duct (venting hose) is fitting, the room shall be provided with air vents
which communicate directly with outside air and are sized in accordance with the
following table:
Room Volume (m
3
)
< 5
5 – 10
> 10
Minimum permanent
opening free area (cm
2
)
100
50
*
Nil
*
If the room has a door which opens directly to outside, no permanent opening is required.
• If humidity duct is connected, air vent is not necessary.
Splashing
With Water
Prohibited
Installation Site
• Do not install the equipment in hot and humid locations
such as bathrooms or in locations (excluding
veranda installations) that are exposed to wind and rain.
Doing so may cause a short circuit, and result in electric shock or fire.
This may also cause the equipment to malfunction.
• When using the equipment outdoors, such as on a
veranda or in the space under the eaves, attach a roof
like a sunshade above the equipment, and install the
optional discharge top.
Water or rainfall directly splashing the equipment may cause a
short circuit, and result in electric shock or fire. This may also
cause the equipment to malfunction.
Discharge top
(option)
Power cord
• Do not pass the power cord under or allow it to come in
contact with the equipment.
Doing so might damage the power cord, and result in electric shock or
fire.
Power cord