background image

Installation instructions

Heat pump dryer
One-family household

1068340-06

03/10/2022

1068340-06

1

Validity

The installation instructions apply to the models: 

12011

12013

Warnings

For Service and Spare Part Information please contact: V-ZUG AUSTRALIA Pty. Ltd. Tel +61 7 3209 6822

The appliance should be installed by qualified personnel only.
Each step must be carried out and checked in full in the order specified.

Check the appliance for visible damage. Do not use the appliance if it is damaged in any way.

Transport the appliance in an upright position only! Transporting it in any other position will result in damage to the
appliance! When carried carefully without being shaken, the appliance may be tilted a maximum of 90° to the left
(viewed from the front).

The appliance must not be supplied through an external switching device, such as a timer, or connected to a circuit
that is regularly switched on and off by a utility.

Room size, room climate and ventilation

Keep all ventilation slits on the appliance clear and unobstructed. Otherwise an adequate supply of air is not guaran-
teed.

Ventilate the room well. Ensure that the temperature of the room is between 5–35 °C.

The room temperature must be kept between the range of 15–25 °C to ensure the economic running of the appliance.

Room size <10 m² (<20 m³)

Room size 

10 m² (≥20 m³)

Room must be ventilated

: There

must be air inlet and outlet openings
to the adjacent room or to the out-
side, e.g. open window/door, ventil-
ation grille or slits in the door or
ventilation system.

Condensation may form on thermal
bridges! The room must therefore
be aired after running several con-
secutive drying programmes, e.g.
by opening a window or door to the
room.

Summary of Contents for AdoraDry V6000

Page 1: ...from the front The appliance must not be supplied through an external switching device such as a timer or connected to a circuit that is regularly switched on and off by a utility Room size room clim...

Page 2: ...e 5 Tower panel W55687 1 Adhering the installation plate to the washing machine see page 5 Condensate drain set incl screw material W56298 1 Connecting condensate drain see page 7 Dimensions The state...

Page 3: ...che depth B based on the niche variants Use two ventilation grilles P33002 or provide a ventilation cross section 1 of min 400 cm2 to conduct the heat that is emitted from the rear of the appliance ou...

Page 4: ...the distance to the back and side walls this applies to indi vidual appliances as well as to a tumble dryer and washing machine positioned next to each other The installation plates for the tumble dr...

Page 5: ...of the manufacturer s guarantee For washing machine models 11001 11006 11010 11014 11021 11023 11025 Take out the double sided adhesive tape 1 and adhere to the mount ing surfaces 2 1 2 2 2 2 For wash...

Page 6: ...e parts and cables with basic insulation must not be accessible Check old installa tions Use at altitude Electrical safety is guaranteed up to 2 000 m above sea level Refer to the identification plate...

Page 7: ...t W56298 Use an open top fixed upright outflow pipe with the drain trap Leave a gap of 5 cm between the end of the drain hose from the tumble dryer and the level of the water in the drain trap Positio...

Page 8: ...er dryer towers Can be connected to a concealed double drain trap Use an open top fixed upright outflow pipe with the drain trap Route drainage pipe separately or use condensate drain kit W55969 W5596...

Page 9: ...est has been run or aborted it can no longer be selected and the appliance enters the normal operating mode Carrying out the function test Insert plug into mains socket In the display appears Language...