Installation instructions
Heat pump dryer
One-family household
1068340-06
03/10/2022
1068340-06
3
Preparing the niche
Changing over the door hinge
If a tumble dryer or a washer-dryer tower is installed in a niche, a 130° door stop must be provided (article no.
W54086).
Niche with doors
If the niche is fitted with a door, hinge the niche door on the same side as the appliance door. Ensure that the niche
door is left open during the process.
B
D
≥605
≥
H
≥5
≥
C
≥5
2
1
3
B
5
4
B
6
4
B
5
4
Niche variant a)
Niche variant b)
Niche variant c)
H
Niche height
≥860
≥1710
≥1710
B
Niche depth
≥605
≥605
≥645
C
Distance to the back wall
≥45
≥50
≥50
D
Installation offset
≥50
≥50
≥83
▸
Determine niche height
H
and niche depth
B
based on the niche variants.
▸
Use two ventilation grilles P33002 or provide a ventilation cross-section
1
of min. 400 cm
2
to conduct the heat that is emitted from
the rear of the appliance out of the niche.
▸
Provide an opening
2
on the left or right for connections and a fresh air supply (≥100 × 100 mm).
▸
Centre the installation plate
3
in the niche.
▸
Observe the distance from the installation plate to the back wall
C
and the side walls.
▸
Observe installation offset
D
for installation plate.
▸
Check for underfloor heating.
▸
Fasten installation plate
3
to the floor (see page 4).
▸
Slide the appliance in.
–
Niche variant a) and b): Niche front
4
and tumble dryer front
5
are flush.
–
Niche variant c): Niche front
4
and washing machine door
6
are flush.
The condensed water hose and connection cable must not be crushed between the rear of the appliance and the wall
or kinked during installation.