Common venting guidelines
Do not common vent with the vent pipe of any other boiler or appliance. However,
20 Common venting guidelines
a common venting system, the common venting system is likely to be too large for
proper venting of the appliances remaining connected to it. The instructions shall
include the test procedure set forth below:
At the time of removal of an excisting boiler, the following steps shall be followed
with each appliance remainning connected to the common venting system placed in
operation, while the other appliancees remaining connected to the common venting
system are not in operation:
(a) Seal any unused openings in the common venting system.
(b) Visually inspect the venting system for proper size and horizontal pitch and deter-
mine there is no blockage or restriction, leakage, corrosion and other deficiencies
which could cause an unsafe condition.
(c) Insofar as is practical, close all building doors and windows and all doors between
the space in which the appliances remaining connected to the common venting
system are located and other spaces of the building. Turn on clothes dryers and
any appliance not connected to the common venting system. Turn on any exhaust
fans, such as range hoods and bathroom exhausts, so they will operate at maxi-
mum speed. Do not operate a summer exhaust fan. Close fireplace dampers.
(d) Place in operation the appliance being inspected. Follow the lighting instructions.
Adjust thermostat so appliance will operate continuously
(e) Test for spillage at the draft hood relief opening after 5 minutes of main burner
operation. Use the flame of a match or candle, or smoke from acigarette, cigar or
pipe.
(f) After it has been determined that each appliance remaining connected to the com-
mon venting system properly vents when tested as outlined above, return doors,
windows, exhaust fans, fireplace dampers and any other gas burning appliance
to their previous condition of use.”
(g) Any improper operation of the common venting system should be corrected so the
installation conforms with the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/
or CAN/CSA B149.1, Natural Gas and Propane Installation Code. When resizing
any portion of the common venting system, the common venting system should
be resized to approach the minimum size as determined using the appropriate
tables in Appendix F in the National Fuel Gas Code, ANSI Z223.1/NFPA 54 and/
or CAN/CSA B149.1, Natural Gas and Propane Installation Codes.
Summary of Contents for Q130SN
Page 18: ...Installation Servicing Instructions Rinnai Q Series 18 Boiler basic piping fig 6 ...
Page 44: ...Installation Servicing Instructions Rinnai Q Series 44 electrical ladder diagram figure 22a ...
Page 99: ...Installation Servicing Instructions Rinnai Q Series 99 ...
Page 119: ...Installation Servicing Instructions Rinnai Q Series 119 ...
Page 120: ......