52
Design indication
Indicative diagrams of operation
Wiring diagram - Connection of external additional module
D6
Mixed circuit pump
D2
Contact probe
for mixed circuits
D5
Mixing valve
B7
DHW recirculation pump
Main electronic board
(lower right corner)
B8
DHW recirculation probe
ζ
ζ
L N N N
H2 M M U+
1
2
3
QX23 QX22 QX21
BX21BX22
L N N N
H2 M M U+
1
2
3
QX23 QX22 QX21
BX21BX22
1
2
3
Micro switches
for extension module selection
D4
B4
Electronic programming - Heat generator for additional circuit setting
Description
Parameter
Selection
Standard Value
Value to set
Heating circuit 1
710
Comfort setpoint
20°C
Between 18 and 22 ° C
712
Reduced setpoint
16°C
Between 15 and 18 ° C
720
Heating curve slope
1,5
1.5 Radiators / 0.8 Floor
741
Flow temp setpoint max
80°C
Radiators 70 ° C / Floor 50 ° C
Configuration
5715
Heating Circuit 2
Off
On
6020
Function extension module 1
-
Heating circuit 2
6021
Function extension module 2
-
Multifunctional
6033
Relay output QX21 module 2
-
Q4 circulation pump
6042
Sensor input BX21 module 2
-
DHW recirculation sensor B39
6047
Contact type H2 module 1
-
Normally Open / Normally Closed