12
GB
Installation
4
4.1
Notes on safety for the installation
After carefully cleaning all around the area where the burner will be installed, and arranging the correct lighting of the environment,
proceed with the installation operations.
4.2
Handling
The packaging of the burner includes a wooden platform (see Ch. 3.5), so it is possible to move the burner (still packaged) with a
transpallet truck or fork lift truck.
With regard to the transport in the obligatory passages, refer to the overall dimensions shown in Fig. 1.
4.3
Preliminary checks
Checking the consignment
After removing all the packaging, check the integrity of the contents. In the event of doubt, do not use the burner; contact the
supplier.
The packaging elements (wooden cage or cardboard box, nails, clips, plastic bags, etc.) must not be abandoned as they are
potential sources of danger and pollution; they should be collected and disposed of in the appropriate places.
Checking the characteristics of the burner
Check the identification label of the burner, showing:
³
the model (see
A
in Fig. 8) and type of burner (
B
);
³
the year of manufacture, in cryptographic form (
C
);
³
the serial number (
D
);
³
the data for electrical supply and the protection level (
E
);
³
the electrical input power (
F
);
³
the types of gas used and the relative supply
pressures (
G
);
³
the data of the burner's minimum and maximum output
possibilities (
H
) (see Firing rate)
Warning.
The output of the burner must be within the
boiler's firing rate;
³
the category of the device/countries of destination (
I
).
4.4
Working position
The burner is designed to operate only in the positions
1
,
2, 3
and
4
.
Installation
1
is preferable, as it is the only one that al-
lows the maintenance operations as described in this
manual. Installations
2
,
3 and 4
permit operation but
make maintenance and inspection of the combustion
head more difficult.
Any other position could compromise the correct opera-
tion of the appliance. Installation
5
is prohibited for
safety reasons.
All the installation, maintenance and disassem-
bly operations must be carried out with the elec-
tricity supply disconnected.
DANGER
The installation of the burner must be carried out
by qualified personnel, as indicated in this man-
ual and in compliance with the standards and
regulations of the laws in force.
WARNING
WARNING
The handling operations for the burner can be highly dangerous if not carried out with the greatest attention: keep any
unauthorised people at a distance; check the integrity and suitableness of the available means of handling.
Check also that the area in which you are working is empty and that there is an adequate escape area (i.e. a free, safe
area to which you can quickly move if the burner should fall).
During the handling, keep the load at not more than 20-25 cm from the ground.
After positioning the burner near the installation point, correctly dispose of all residual packaging, separating the various
types of material.
Before proceeding with the installation operations, carefully clean all around the area where the burner will be installed.
CAUTION
CAUTION
R.B.L.
GAS-KAASU
GAZ-AEPIO
0085
RIELLO S.p.A.
I-37045 Legnago (VR)
CE
Fig. 8
A burner label that has been tampered with, re-
moved or is missing, along with anything else that
prevents the definite identification of the burner and
makes any installation or maintenance work diffi-
cult.
WARNING
D7738
A
B
C
E
D
F
H
G
G
H
I
2
3
4
5
1
D7739
Fig. 9
Summary of Contents for RS 100/E MZ
Page 45: ...45 GB Appendix Electrical panel layout A ...
Page 46: ...46 GB Appendix Electrical panel layout A ...
Page 47: ...47 GB Appendix Electrical panel layout A ...
Page 48: ...48 GB Appendix Electrical panel layout A ...
Page 49: ...49 GB Appendix Electrical panel layout A ...
Page 54: ......
Page 55: ......