Page 23 of 88
Di splay
The system display will identify an un-configured device by horizontal bars on all displays.
RN.300 Display of an un-configured device
RN.300 devices have the following factory default settings:
RN.301.MI
RN.302.LO
RN.332. DO
RN.333. DI
MUTE:
OFF
MUTE:
OFF
MUTE:
OFF
MUTE:
OFF
GAIN:
0dB
CLIP
LEV EL:
24dB u
PHANTOM
POWER:
OFF
Unity Gain
The factory default setting of 0dB gain at the RN.301.MI microphone preamp / line level input and
+24dBu clip level at the RN.302.LO is the so called unity gain setting. With thes e settings a signal will
pass the network with no level adjustments.
E XAMPLE:
An input signal of 10dBu fed into the RN.301.MI will occur at a level of 10dBu at the RN.302.LO output
if the gain adjustment at the RN.301.MI is set to 0dB and the level adjustment at the RN.302.LO is set
to +24dBu.
The input level can be attenuated to -6dB and the output level can have a maximum attenuation of
33dB (to -9dB u).
The maximum output level of an RN.302.LO is +24dB u.
The maximum input level of an RN.301.MI is 30dB u (if the input attenuation is adjusted to -6dB ).
Fan
A ventilation fan mounted on the rear panel will ensure permanent proper cooling as soon t he device
is connected to mains.
USO