8.8 ADJUSTING THE POSITION OF THE INK DETECTING PIN
Purpose: To ensure detection of ink built-up between the ink roller and the
doctor roller.
Adjustment Standard: 5
±
1 mm
1. Remove the drum unit.
2. Remove the tetron screen and the metal screen from the drum unit.
3. Remove the ink distributer (2 screws).
4. Wipe off the ink around the ink roller [A] and the doctor roller [B].
5. Make sure that the distance between the end of the ink detecting pin [C]
and the doctor roller [B] surface is 5
±
1 mm.
6. If it is not, loosen the screw [D] and adjust the distance by moving the ink
detecting pin [C].
7. After adjusting, retighten the screw [D].
5
±
1 mm
[A]
[B]
[D]
[C]
[A]
[B]
1 December 1993
5-63
Summary of Contents for VT3500
Page 8: ...2 6 USER CODE MODE 4 27 2 6 1 User Codes 4 27 2 6 2 How To Use a User Code 4 27...
Page 15: ...SECTION 1 OVERALL MACHINE INFORMATION...
Page 19: ...2 GUIDETOCOMPONENTSANDTHEIRFUNCTION 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 1 December 1993 1 5...
Page 21: ...16 17 18 19 20 21 22 23 24 25 26 27 28 1 December 1993 1 7...
Page 37: ...SECTION 2 SECTIONAL DESCRIPTION...
Page 89: ...E H D G F D C A B C I J K 1 December 1993 2 53...
Page 123: ...1 December 1993 2 87...
Page 127: ...1 December 1993 2 91...
Page 162: ...13 14 15 16 17 18 10 11 12 1 December 1993 2 126...
Page 163: ...19 20 21 22 23 24 25 26 27 1 December 1993 2 127...
Page 164: ...28 29 30 31 32 33 34 35 36 1 December 1993 2 128...
Page 165: ...37 38 39 40 1 December 1993 2 129...
Page 192: ...SECTION 3 INSTALLATION...
Page 206: ...SECTION 4 SERVICE TABLES...
Page 209: ...Q Fig 4 R S Fig 5 T U Fig 6 V Fig 7 1 December 1993 4 3...
Page 234: ...SECTION 5 REPLACEMENT AND ADJUSTMENT...
Page 317: ...SECTION 6 TROUBLESHOOTING...