002
After Job End
ENG
[0 to 10 / 5 / 1 sec/step]
Specifies the idling time without the lamp on after job end.
This idling prevents the heating roller overheating after job end.
1118
[Curl Correction]
001
Execute Pattern
*ENG
[0 to 4 / 0 / 1]
Selects the curl correction mode.
0: Invalid
1: 600 dpi
2: 1200 dpi
3: 600/1200 dpi
• This SP is not effective for all curl situations. Use this SP if you see a sharp back curl after
the machine recovered from "OFF mode" in a high temperature and humidity
environment.
002
Humidity Thresh 1
*ENG
[0 to 100 / 65 / 1 %]
Specifies the first threshold humidity for executing the curl correction.
003
Humidity Thresh 2
*ENG
[0 to 100 / 80 / 1 %]
Specifies the second threshold humidity for executing the curl correction.
004 Pattern 1: MM: H-Roll
*ENG
[-30 to 0 / -3 / 1 deg]
005 Pattern 1: MM: P-Roll
*ENG
[0 to 60 / 0 / 1 deg]
006 Pattern 1: HM: H-Roll
*ENG
[-30 to 0 / 0 / 1 deg]
007 Pattern 1: HM: P-Roll
*ENG
[0 to 60 / 0 / 1 deg]
008 Pattern 2: MM: H-Roll
*ENG
[-30 to 0 / -5 / 1 deg]
009 Pattern 2: MM: P-Roll
*ENG
[0 to 60 / 50 / 1 deg]
010 Pattern 2: HM: H-Roll
*ENG
[-30 to 0 / -5 / 1 deg]
011 Pattern 2: HM: P-Roll
*ENG
[0 to 60 / 50 / 1 deg]
1119
[Fusing FF Control] DFU
System SP-xxx
35
3
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Summary of Contents for M022
Page 2: ...CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 23: ...INDEX 743 21 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 24: ...22 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 27: ...Overview Component Layout Overview 25 1 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 34: ...1 Product Information 32 1 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 112: ...13 Reassemble the machine 2 Installation 110 2 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 128: ...2 Installation 126 2 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 132: ...3 Preventive Maintenance 130 3 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 303: ...5 HVPS D A x 3 x 1 Duplex Unit 301 4 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 365: ...2 SDB A x 4 x 2 Electrical Components 363 4 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 366: ...4 Replacement and Adjustment 364 4 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 628: ...5 System Maintenance 626 5 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 644: ...5 System Maintenance 642 5 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 738: ...6 Troubleshooting 736 6 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 746: ...CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 758: ...1 Appendix Specifications 12 1 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 764: ...2 Appendix Preventive Maintenance Tables 18 2 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...