002
Pre-Idling Time
*ENG
[0 to 120 / 0 / 1 sec/step]
Specifies the fusing rotation time before executing SP1109-001.
003
Stop Time
* ENG
[5 to 30 / 20 / 1 sec/step]
Specifies the time for measuring the nip.
1112
[Envir. Correct: Fusing]
001
Temp.: Threshold: Low
*ENG
[10 to 23 / 17 / 1 deg/step]
Specifies the threshold temperature for low temperature condition.
002
Temp.: Threshold: High
*ENG
[24 to 40 / 30 / 1 deg/step]
Specifies the threshold temperature for high temperature condition.
003
Low Temp. Correction
*ENG
[0 to 15 / 5 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the low temperature
condition (specified with SP1112-001) is detected, the value of this SP is added to the heating
roller temperature.
004
High Temp. Correction
*ENG
[0 to 15 / 3 / 1 deg/step]
Specifies the temperature correction for the heating roller. When the high temperature
condition (specified with SP1112-002) is detected, the value of this SP is subtracted from
the heating roller temperature.
005 Offset Temp:Low
*ENG
[0 to 15 / 5 / 0.1 deg/step]
006 Offset Temp:High
*ENG
[0 to 15 / 3 / 0.1 deg/step]
1113
[Stand-by Mode Setting]
001
Wait Time AF Ready
*ENG
[0 to 60 / 30 / 1 sec/step]
003
Wait Time AF Recovery
*ENG
[0 to 60 / 10 / 1 sec/step]
Specifies the time for keeping the target temperature without any jobs after recovery
(SP1105-083).
004
Wait Time AF Job
*ENG
[0 to 60 / 10 / 1 sec/step]
Specifies the time for keeping the target temperature without any jobs after a last job.
3. Appendix: SP Mode Tables
32
3
CÓPIA NÃO CONTROLADA
CÓPIA NÃO CONTROLADA
Summary of Contents for M022
Page 2: ...CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 23: ...INDEX 743 21 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 24: ...22 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 27: ...Overview Component Layout Overview 25 1 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 34: ...1 Product Information 32 1 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 112: ...13 Reassemble the machine 2 Installation 110 2 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 128: ...2 Installation 126 2 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 132: ...3 Preventive Maintenance 130 3 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 303: ...5 HVPS D A x 3 x 1 Duplex Unit 301 4 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 365: ...2 SDB A x 4 x 2 Electrical Components 363 4 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 366: ...4 Replacement and Adjustment 364 4 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 628: ...5 System Maintenance 626 5 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 644: ...5 System Maintenance 642 5 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 738: ...6 Troubleshooting 736 6 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 746: ...CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 758: ...1 Appendix Specifications 12 1 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...
Page 764: ...2 Appendix Preventive Maintenance Tables 18 2 CÓPIA NÃO CONTROLADA CÓPIA NÃO CONTROLADA ...