General
Tab
> General Information
Cont’d
•
Machine Reset Time (Seconds)
(required) – Enter the reset time (max. 600
seconds). By default, logout is automatic if the MFD is idle for 60 seconds, i.e., no
buttons on the MFD are pressed.
Note
: The Machine Reset Time cannot be less than the Keep-alive Timer.
•
Keep-alive Timer
(required) – Enter the time in which the session remains open
(max. 585 seconds). This number will define the time interval at which the MFDs will
contact the server with a request to keep the server session alive. The Keep-alive
Timer must be at least 15 seconds
less than
the Machine Reset Time. Since
Machine Reset Time can range from 60 to 600 seconds, the Keep-alive Timer has a
valid range from 45 to 585 seconds (default: 45 seconds).
B.
Default Scan Settings
The GlobalScan user can override resolution, scan type (color/mono), batch scan,
duplex, original orientation and file format defaults by selecting another setting on
the MFD control panel. The default value is restored after the user logs out (or after
MFD timeout).
•
Default Scan Resolution
-
From this drop-down, select 200-, 300- or 400-dpi as
the default scan resolution for the machine profile. For example, MFD users in
the advertising department may require a higher resolution than those in another
department.
Scan Mode
Resolution Scan Size
Scan Type
*
Image Density
Default
200 dpi
Auto Detect
B&W or Color
Auto Density
Fine
300 dpi
Auto Detect
B&W or Color
Auto Density
Super Fine
400 dpi
Auto Detect
B&W or Color
Auto Density
*
Color is supported on select MFDs.
•
Default Color Enabled
– Select on or off. When checked (on), all documents
scanned on a color MFD are uploaded in color. If this box is unchecked (off),
documents are uploaded in black & white.
Default Scan Settings
can be overridden on
the project level