Num.
Sensor/Switch
Bit2
Bit1
Bit0
042
BCU Version
Ver.1
Ver.2
Ver.3
Output Check (SP5-804)
Conducting Output Check
• To prevent mechanical or electrical damage, do not keep an electrical component on for a long
time.
1. Select SP5-804.
2. Select the number (see the table below) corresponding to the component.
3. Select "ON."
4. To stop the operation, select "OFF."
Output Check Table
Num.
Component
001
Main Motor: CW: High
003
Main Motor: CCW: High
020
Toner Bottle Motor
025
Exhaust Fan Motor: High
026
Exhaust Fan Motor: Low
028
CTL Fan
032
Registration CL
033
1st Paper Feed CL
040
Fusing SOL
041
Dehumidification Heater
042
P.P.: Image Transfer: -
System Service Mode
147
Summary of Contents for D127
Page 1: ...Model S C5 Machine Code D127 D128 Field Service Manual 24 February 2012...
Page 2: ......
Page 14: ...Model S C5 201 12...
Page 28: ...1 Product Information 26...
Page 48: ...10 Remove the controller box 10 x 2 x 6 11 Remove the support bracket 11 x 3 2 Installation 46...
Page 54: ...11 Remove the controller box 11 x 2 x 6 12 Remove the support bracket 12 x 3 2 Installation 52...
Page 132: ...5 Holder A x 1 6 Hinge A x 3 7 Bracket A x 2 4 Replacement and Adjustment 130...
Page 135: ...3 Registration sensor A x 1 hooks ARDF 133...
Page 158: ...5 System Maintenance Reference 156...
Page 198: ...6 Troubleshooting 196...
Page 206: ...MEMO 204 EN...
Page 207: ...Model S C5 Machine Code D127 D128 Appendices 26 November 2011...
Page 208: ......
Page 212: ...4...
Page 365: ...For the settings of the image quality see the copier SP mode table System Service Mode 157...
Page 366: ...3 Appendix SP Mode Tables 158...