No
FUNCTION
COMMENTS
0-7
Extension access code (0 to 7) to
turn V.8 protocol On/Off
0: On
1: Off
If the PABX does not support V.8/V.34 protocol
procedure, set this bit to “1” to disable V.8.
Example: If “0” is the PSTN access code, set bit 0 to 1.
When the machine detects “0” as the first dialed number,
it automatically disables V.8 protocol. (Alternatively, if
“3” is the PSTN access code, set bit 3 to 1.)
Communication Switch 1C [SP No. 1-104-029]
No
FUNCTION
COMMENTS
0-1
Extension access code (8 and 9)
to turn V.8 protocol On/Off
0: On
1: Off
Refer to communication switch 1B.
Example: If “8” is the PSTN access code, set bit 0 to 1.
When the machine detects “8” as the first dialed number,
it automatically disables V.8 protocol. (If “9” is the PSTN
access code, use bit 1.)
2-7 Not used
Do not change the settings.
Communication Switch 1D - Not used (do not change the settings)
Communication Switch 1E - Not used (do not change the settings)
Communication Switch 1F - Not used (do not change the settings)
G3-1 Switches
G3 Switch 00 [SP No. 1-105-001]
No
FUNCTION
COMMENTS
0-1
Monitor speaker during
communication (tx and rx)
Bit 1: 0, Bit 0: 0 = Disabled
Bit 1: 0, Bit 0: 1 = Up to Phase B
Bit 1: 1, Bit 0: 0 = All the time
Bit 1: 1, Bit 0: 1 = Reserved
(0, 0): The monitor speaker is disabled all through the
communication.
(0, 1): The monitor speaker is on up to phase B in the T.
30 protocol.
(1, 0): Used for testing. The monitor speaker is on all
through the communication. Make sure that you reset
these bits after testing.
Bit Switches
225
Summary of Contents for D127
Page 1: ...Model S C5 Machine Code D127 D128 Field Service Manual 24 February 2012...
Page 2: ......
Page 14: ...Model S C5 201 12...
Page 28: ...1 Product Information 26...
Page 48: ...10 Remove the controller box 10 x 2 x 6 11 Remove the support bracket 11 x 3 2 Installation 46...
Page 54: ...11 Remove the controller box 11 x 2 x 6 12 Remove the support bracket 12 x 3 2 Installation 52...
Page 132: ...5 Holder A x 1 6 Hinge A x 3 7 Bracket A x 2 4 Replacement and Adjustment 130...
Page 135: ...3 Registration sensor A x 1 hooks ARDF 133...
Page 158: ...5 System Maintenance Reference 156...
Page 198: ...6 Troubleshooting 196...
Page 206: ...MEMO 204 EN...
Page 207: ...Model S C5 Machine Code D127 D128 Appendices 26 November 2011...
Page 208: ......
Page 212: ...4...
Page 365: ...For the settings of the image quality see the copier SP mode table System Service Mode 157...
Page 366: ...3 Appendix SP Mode Tables 158...