1. Scanner Cover and Exposure Glass ( p.83 " Scanner Cover and Exposure Glass")
2. Remove the long bracket [A] and the guide rod bracket [B]. ( x 4)
3. Lift the guide rod [C] as the red arrow shows.
4. Put the belt [D] off as blue arrow shows to release the LED Unit [E] from the guide rod.
• Do not loosen the paint-locked screws holding the lens in place.
• After installing a new lens, carry out copy adjustments ( p.134 "Adjusting Copy Image
Scanner Motor
4. Replacement and Adjustment
84