Rich Electric Co. “SuperCombi” User Manual V7.19 Copyright 2009
Page 75
MODE 4:
Renewable Energy has Priority to Charge the batteries
with AC Charger Support. The Combi Inverter has Priority
to Support the AC load with AC Power Support.
When SuperCombi enters to MODE 4, B2-09(AC IN DynaCur Limit)=0 (Disable) and the value
of B2-19 (MODE4: ACINCurrent Lmt)will be loaded to B2-05.
1. INVERTER Mode:
z
When the battery voltage is not lower than (B2-10) voltage value, inverter mode takes
priority to supply voltage to AC OUT for load consumption.
(INVERTER ON+ ATS OFF + AC CHARGER OFF)
Battery
Shore Power
Ready
Load
ATS OFF
AC IN
AC OUT
3A
5A
B2-05=5A
3A
45A
Solar
Charger
Solar Panel
or