Rich Electric Co. “SuperCombi” User Manual V7.19 Copyright 2009
Page 88
B2-10: MODE4: Bat Lo?V ATS ON
B2-11: MODE4: Bat Lo?S ATS ON
B2-12: MODE4: Bat Hi?V ATSOFF
B2-13: MODE4: Bat Hi?S ATSOFF
B2-14: MODE3: Bat Lo?V ATS ON
B2-15: MODE3: Bat Lo?S ATS ON
B2-16: MODE3: Bat Hi?V ATSOFF
B2-17: MODE3: Bat Lo?S ATSOFF
B2-10~B2-13 are used to set the condition of ATS to be ON/OFF in MODE4
B2-14~B2-17 are used to set the condition of ATS to be ON/OFF in MODE3
z
When SuperCombi® is in either MODE4 or MODE3, INVERTER mode takes priority to
supply voltage to AC OUT for load consumption. When AC IN power is ready, INVERTER is
active and battery is about to be exhausted, ATS will be switched on to ensure AC OUT to
continuously supply the load. At the moment, AC OUT will be supplied by AC IN power. At the
same time, the battery can be charged by other renewable energy such as solar charger, wind
charger or DC generator charger (MODE3) which is normally the solar house application in no
need of AC CHARGER.
z
MODE3: B2-14 and B2-15 are used to set ATS to be “ON” when the battery voltage is lower
than B2-14 voltage value and longer than the second time set in B2-15 in MODE3.
(ATS ON+INVERTER OFF+AC CHARGER ON)
z
MODE 3: B2-16 and B2-17 are used to set ATS to be “OFF” when the battery voltage is higher
than B2-16 voltage value and longer than the second time set in B2-17 in MODE3.
(INVERTER ON+ATS OFF+ AC CHARGER OFF)
z
In (MODE 4) The battery can be charged by AC IN (AC CHARGER) or other renewable
energy such as solar charger, wind charger or DC generator charger which is normally the
application requesting both AC charging and DC charging.
When charging battery slowly reaches to certain level, this means battery will be fully charged
soon and the ATS will be switched off for INVERTER to take over the ongoing supply to AC
OUT for load.
z
MODE 4: B2-10 and B2-11 are used to set ATS to be “ON” when the battery voltage is lower
than B2-10 voltage value and longer than the second time set in B2-11 in MODE4.
(INVERTER OFF+ATS ON+AC CHARGER ON)
z
MODE 4: B2-12 and B2-13 are used to set ATS to be “OFF” when the battery voltage is higher
than B2-12 voltage value and longer than the second time set in B2-13 in MODE4.
(INVERTER ON+ATS OFF+AC CHARGER OFF)
Summary of Contents for Invertek SuperCombi SC-1500-12X
Page 1: ......
Page 2: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 2...
Page 9: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 9 Layout...
Page 125: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 125 Chapter 8 Constants list...
Page 155: ...Rich Electric Co SuperCombi User Manual V7 19 Copyright 2009 Page 155 NOTES...